Microtek Online UPS 1KVA/36V E2

Microtek High-Frequency Online UPS provides Uninterrupted Pure Power for Critical Applications such as Computer Network, Servers, Cyber Cafes, ATM Machines, and CCTV Camera, etc. Microtek offers a Wide Range of Online UPS from 1KVA to 40KVA based on World’s Latest Technology to meet the harsh Environmental and worst Power Conditions for Applications from Small Office requirement to Space Critical Missions with a wide variety of Backup Range from 5 minutes to 10 hours to meet the needs of every individual.

Deliver to: //

SKU: 8813 Category:

Description

Microtek Online UPS 1KVA/36V E2

High Frequency and Hybrid Double Conversion Online Technology.
High-End IGBT Based.
High-End Micro Controller Based.
Wide Input Voltage Range
Advanced PFC Technology
Advanced Battery Management
Automatic Battery Charging in UPS Off Mode
Short Circuit and Overload Protection
Smart RS232 communication with monitoring software
SNMP Card Slot (Optional)
Over Temperature Protection.
EMI / RFI Noise Filter
LCD/LED Display simultaneously
Specially designed to suit Indian Power and Environment Conditions
Generator Compatible (Supplying Sinewave Voltage)
Isolation Transformer (Optional)
Different Output Voltage settings.
Output Frequency fixed at 50Hz or can be synchronized with Input Frequency.
Static Bypass Enable or Disable.
Outlets Programmable and Non-Programmable.
Protection from DC Fan failure.
In-built Over Voltage Cut-Off Device.

Features

Technical Specifications
Model E² Series
Rated Capacity 1 KVA / 800 Watts
Input
Input Voltage Range (Load < 50%) 118 ~ 295 V (± 5 V)
Input Voltage range ((Load > 50%)) 160 ~ 295 V (± 5 V)
Frequency 40 ~ 70 Hz
Phase Single Phase with Ground
Power Factor ≥ 0.99 @ full load
 
Output
Voltage Range 208 / 220 / 230 / 240 V AC
Frequency Range (Synchronized Range)

Frequency Range (Battery Mode)

47 ~ 53 Hz or 57 ~ 63 Hz

50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz

THD (Linear Load) ≤ 2%
THD (Non Linear Load) ≤ 4%
Overload > 110%, 30s turn to Bypass Mode
  > 150% instant turn to Bypass
Crest Factor 3:1 (Max)
Short Circuit Protection 5 cycles turn Off Inverter, no transfer to Bypass, provide Alarm (AC Mode), 5 cycles turn Off Inverter, provide Alarm(Battery Mode), Input Fuse blown or Breaker action
Waveform Pure Sinewave
Transfer Time

(AC Mode to Battery Mode)

(Inverter to Bypass Mode)

Zero

< 4 ms

Efficiency 85%~ 92%
Battery
DC Voltage 36 V
Charge Current 6.5 A
Communication Interface RS232,SNMP (Optional)
Indication LCD Display
Noise Level Less than 50dBA @ 1 Meter (With Fan Speed Control)
UPS Overload / UPS Short-Circuit 110% / 300%
Warranty   One Year